Inductor DCR & Copper Loss

Correct copper DCR for winding temperature and estimate resistive loss. Compare two inductors under the same operating conditions.

Calculations run locally. Save is device-only; sharing includes the entered values.

Operating conditions

Units are fixed beside each field: V, A, kHz, µH, mΩ and °C.

Currents are recalculated from the shared Buck inputs, including negative inductance tolerance.

12–12 V → 5 V · 3 A · 500 kHz · 10 µH ±20%

Edit Buck conditions
mΩ
mΩ
°C
°C

Calculation results

Temperature-adjusted DCR
26.288 mΩ
Estimated copper loss
0.23776 W
DCR change
31.44 %
RMS current
3.0074 A

Loss versus winding temperature

Winding temperature (°C)Inductor A (mΩ)Inductor A (W)
-4015.2840.13823
20200.18089
6023.1440.20932
10026.2880.23776
15030.2180.2733

Model & formulas

Copper approximation: α20 = 0.00393 / °C; supported winding/reference temperatures −100 to 200 °C. Temperature is an input, not a predicted rise. I²R excludes core and additional high-frequency winding losses. Both inductors use the same temperature and DCR basis. Typical DCR is not a guaranteed upper bound.

Ideal steady-state, nonnegative CCM model with fixed frequency. Worst ripple occurs at maximum input voltage and minimum L from tolerance. DC bias, temperature-related inductance change, controller limits, startup and transients are not modeled. Check the controller datasheet and real waveforms.

R(T) = R(Tref) × [1 + α20(T−20)] / [1 + α20(Tref−20)]

P = Irms² × R(T)

Irms = √(Iavg² + ΔI²/12)

Technical references

Questions, examples and engineering limits

Estimate DC copper loss with RMS current and temperature-adjusted DCR. Distinguish winding DC loss from AC winding loss and core loss.

Content updated:

How is Inductor Copper Loss Calculator: DCR and Temperature calculated?

Use R(T) = R20[1 + 0.00393(T−20)]; Pdc = Irms² R(T). Estimate DC copper loss with RMS current and temperature-adjusted DCR. Distinguish winding DC loss from AC winding loss and core loss.

Sources: coilcraft.com [1]

How do I calculate this example: R20 = 0.1 Ω, T = 100 °C, Irms = 2 A?

R(T) = 0.13144 Ω; Pdc = 0.52576 W. This is a calculated example under the model stated above; it is not a measured component specification.

Which units does Inductor Copper Loss Calculator: DCR and Temperature use?

Ω, mΩ, A, °C, W. Convert prefixes before substituting values; keep the input and output units attached to every number.

Sources: coilcraft.com [1]

Can this result predict temperature rise?

No. Temperature rise also requires loss data, mounting, airflow and a validated thermal model. A calculated electrical value is not a thermal qualification.

Sources: coilcraft.com [1]

Are saturation current and RMS current interchangeable?

No. Compare peak current with the specified saturation criterion and RMS current with the thermal rating under its test conditions.

Sources: coilcraft.com [1]

Does DCR include skin and proximity effects?

No. DCR is a DC quantity. AC winding resistance depends on frequency, conductor geometry and winding arrangement; core loss needs its own material model.

Sources: coilcraft.com [1]

Answers use the stated model and units. Examples are calculated values, not measurements or component ratings.