Inductor DCR & Copper Loss

Correct copper DCR for winding temperature and estimate resistive loss. Compare two inductors under the same operating conditions.

Calculations run locally. Save is device-only; sharing includes the entered values.

Manufacturer part used for imported values: SRP5030TA-3R3M

Manufacturer ratings are populated. Review their test conditions before use. Converter current is recalculated after changing inductance.

Review source conditions and comparison

Operating conditions

Units are fixed beside each field: V, A, kHz, µH, mΩ and °C.

A
A

Use DC or a nonnegative continuous triangular current. For nonzero ripple, average current must exceed half the peak-to-peak ripple. Pulsed/DCM and reverse-current waveforms require another model.

mΩ
mΩ
°C
°C

Calculation results

Temperature-adjusted DCR
48.985 mΩ
Estimated copper loss
0.44417 W
DCR change
28.907 %
RMS current
3.0112 A

Inductor B

Temperature-adjusted DCR
30.035 mΩ
Estimated copper loss
0.27235 W
Loss B − A
-0.17182 W

Loss versus winding temperature

Winding temperature (°C)Inductor A (mΩ)Inductor A (W)Inductor B (W)
-4028.480.258240.15834
2037.2680.337920.2072
6043.1260.391050.23977
10048.9850.444170.27235
15056.3080.510570.31306

Model & formulas

Copper approximation: α20 = 0.00393 / °C; supported winding/reference temperatures −100 to 200 °C. Temperature is an input, not a predicted rise. I²R excludes core and additional high-frequency winding losses. Both inductors use the same temperature and DCR basis. Typical DCR is not a guaranteed upper bound.

R(T) = R(Tref) × [1 + α20(T−20)] / [1 + α20(Tref−20)]

P = Irms² × R(T)

Irms = √(Iavg² + ΔI²/12)

Technical references

Questions, examples and engineering limits

Estimate DC copper loss with RMS current and temperature-adjusted DCR. Distinguish winding DC loss from AC winding loss and core loss.

Content updated:

How is Inductor Copper Loss Calculator: DCR and Temperature calculated?

Use R(T) = R20[1 + 0.00393(T−20)]; Pdc = Irms² R(T). Estimate DC copper loss with RMS current and temperature-adjusted DCR. Distinguish winding DC loss from AC winding loss and core loss.

Sources: coilcraft.com [1]

How do I calculate this example: R20 = 0.1 Ω, T = 100 °C, Irms = 2 A?

R(T) = 0.13144 Ω; Pdc = 0.52576 W. This is a calculated example under the model stated above; it is not a measured component specification.

Which units does Inductor Copper Loss Calculator: DCR and Temperature use?

Ω, mΩ, A, °C, W. Convert prefixes before substituting values; keep the input and output units attached to every number.

Sources: coilcraft.com [1]

Can this result predict temperature rise?

No. Temperature rise also requires loss data, mounting, airflow and a validated thermal model. A calculated electrical value is not a thermal qualification.

Sources: coilcraft.com [1]

Are saturation current and RMS current interchangeable?

No. Compare peak current with the specified saturation criterion and RMS current with the thermal rating under its test conditions.

Sources: coilcraft.com [1]

Does DCR include skin and proximity effects?

No. DCR is a DC quantity. AC winding resistance depends on frequency, conductor geometry and winding arrangement; core loss needs its own material model.

Sources: coilcraft.com [1]

Answers use the stated model and units. Examples are calculated values, not measurements or component ratings.