My favorites

Inductor Current Check

Check peak and RMS inductor currents against saturation and thermal ratings, with explicit datasheet conditions.

Calculations run locally. Save is device-only; sharing includes the entered values.

Operating conditions

Units are fixed beside each field: V, A, kHz, µH, mΩ and °C.

Currents are recalculated from the shared Buck inputs, including negative inductance tolerance.

12–12 V → 5 V · 3 A · 500 kHz · 10 µH ±20%

Edit Buck conditions
A
A
A

Calculation results

Peak current
3.3646 A
RMS current
3.0074 A
Peak used for saturation check
3.3646 A

Saturation current Isat (optional)

Conditions/data incomplete

Rating headroom: —%

Thermal current rating (optional)

Conditions/data incomplete

Rating headroom: —%

Review both rating conditions before using the result.

Estimate copper loss →

Optional candidate limits

Leave blank for no limit. DCR is the published maximum at 25°C. Overall long/short sides include tolerances and terminals; height uses the mounted limit. Check the original pre-mount, stand-off and operating dimensions. Envelope matching does not verify pad layout, DC bias or PCB thermal performance.

mΩ
mm
mm
mm

Catalogue records for engineering review

31 source-reviewed power inductor records. Each converter record uses its own L and tolerance. Numeric matches remain preliminary; verify bias, losses, PCB temperature and transient margins.

Browse all source-reviewed power records →

Numeric matches awaiting engineering review

No application-qualified candidate is established by this library; test evidence remains to be reviewed.

  • XAL5050-822MEC

    8.2 µH ±20% · DCR max: 34.95 mΩ

    Overall envelope including tolerances and terminals: 5.68 × 5.48 × 5.1 mm

    Source temperature range: -40…125°C (ambient with rated rise)

    Required peak
    3.4446 A
    Required RMS
    3.011 A
    Recalculated ripple
    0.88923 A

    Published Isat / L drop: 5.6 A / 30% · 25°C

    Published Irms / rise / ambient: 6.1 A / 40°C / 25°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture

    Original source: XAL50xx · Document 908 · 02/26/26 · Source checked:

  • XAL5050-103MEC

    10 µH ±20% · DCR max: 45 mΩ

    Overall envelope including tolerances and terminals: 5.68 × 5.48 × 5.1 mm

    Source temperature range: -40…125°C (ambient with rated rise)

    Required peak
    3.3646 A
    Required RMS
    3.0074 A
    Recalculated ripple
    0.72917 A

    Published Isat / L drop: 4.9 A / 30% · 25°C

    Published Irms / rise / ambient: 4.9 A / 40°C / 25°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture

    Original source: XAL50xx · Document 908 · 02/26/26 · Source checked:

  • XAL5050-153MEC

    15 µH ±20% · DCR max: 76.7 mΩ

    Overall envelope including tolerances and terminals: 5.68 × 5.48 × 5.1 mm

    Source temperature range: -40…125°C (ambient with rated rise)

    Required peak
    3.2431 A
    Required RMS
    3.0033 A
    Recalculated ripple
    0.48611 A

    Published Isat / L drop: 3.7 A / 30% · 25°C

    Published Irms / rise / ambient: 3.9 A / 40°C / 25°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture

    Original source: XAL50xx · Document 908 · 02/26/26 · Source checked:

  • XAL5050-223MEC

    22 µH ±20% · DCR max: 99.65 mΩ

    Overall envelope including tolerances and terminals: 5.68 × 5.48 × 5.1 mm

    Source temperature range: -40…125°C (ambient with rated rise)

    Required peak
    3.1657 A
    Required RMS
    3.0015 A
    Recalculated ripple
    0.33144 A

    Published Isat / L drop: 3.6 A / 30% · 25°C

    Published Irms / rise / ambient: 3.4 A / 40°C / 25°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture

    Original source: XAL50xx · Document 908 · 02/26/26 · Source checked:

Compare test conditions →

Model & formulas

Isat is defined at a manufacturer-specific inductance drop; thermal ratings depend on permitted temperature rise and test setup. Headroom is (rating − demand) / rating. A within-rating result is conditional, not a complete design approval. Startup/fault peak affects the saturation check only.

Ideal steady-state, nonnegative CCM model with fixed frequency. Worst ripple occurs at maximum input voltage and minimum L from tolerance. DC bias, temperature-related inductance change, controller limits, startup and transients are not modeled. Check the controller datasheet and real waveforms.

Ipeak = Iavg + ΔI/2

Irms = √(Iavg² + ΔI²/12)

Technical references

Questions, examples and engineering limits

Calculate triangular-ripple peak and RMS current, then compare saturation and thermal limits. Understand rating conditions and required margin.

Content updated:

How is Inductor Current Check: Peak, RMS, Isat and Irms calculated?

Use Ipeak = Iavg + ΔIpp/2; Irms = √(Iavg² + ΔIpp²/12). Calculate triangular-ripple peak and RMS current, then compare saturation and thermal limits. Understand rating conditions and required margin.

Sources: coilcraft.com [1]

How do I calculate this example: Iavg = 2 A, ΔIpp = 0.6 A?

Ipeak = 2.3 A; Irms ≈ 2.007486 A. This is a calculated example under the model stated above; it is not a measured component specification.

Which units does Inductor Current Check: Peak, RMS, Isat and Irms use?

A, mA, %. Convert prefixes before substituting values; keep the input and output units attached to every number.

Sources: coilcraft.com [1]

Are saturation current and RMS current interchangeable?

No. Compare peak current with the specified saturation criterion and RMS current with the thermal rating under its test conditions.

Sources: coilcraft.com [1]

Is nominal inductance constant at every current?

No. DC bias, temperature and measurement frequency can change inductance. Use the manufacturer’s curves for the selected part rather than assuming a constant value.

Sources: coilcraft.com [1]

Can this result predict temperature rise?

No. Temperature rise also requires loss data, mounting, airflow and a validated thermal model. A calculated electrical value is not a thermal qualification.

Sources: coilcraft.com [1]

Answers use the stated model and units. Examples are calculated values, not measurements or component ratings.