My favorites

Inductor Current Check

Check peak and RMS inductor currents against saturation and thermal ratings, with explicit datasheet conditions.

Calculations run locally. Save is device-only; sharing includes the entered values.

Manufacturer part used for imported values: XAL5030-332MEC

Manufacturer ratings are populated. Review their test conditions before use. Converter current is recalculated after changing inductance.

Review source conditions and comparison

Operating conditions

Units are fixed beside each field: V, A, kHz, µH, mΩ and °C.

A
A
µH

Use DC or a nonnegative continuous triangular current. For nonzero ripple, average current must exceed half the peak-to-peak ripple. Pulsed/DCM and reverse-current waveforms require another model.

A
A
A

Calculation results

Peak current
3.45 A
RMS current
3.0112 A
Peak used for saturation check
3.45 A

Saturation current Isat (optional)

Conditions/data incomplete

Rating headroom: 60.345%

Thermal current rating (optional)

Conditions/data incomplete

Rating headroom: 62.824%

Review both rating conditions before using the result.

Estimate copper loss →

Optional candidate limits

Leave blank for no limit. DCR is the published maximum at 25°C. Overall long/short sides include tolerances and terminals; height uses the mounted limit. Check the original pre-mount, stand-off and operating dimensions. Envelope matching does not verify pad layout, DC bias or PCB thermal performance.

mΩ
mm
mm
mm

Catalogue records for engineering review

31 source-reviewed power inductor records. Each converter record uses its own L and tolerance. Numeric matches remain preliminary; verify bias, losses, PCB temperature and transient margins.

Browse all source-reviewed power records →

Numeric matches awaiting engineering review

No application-qualified candidate is established by this library; test evidence remains to be reviewed.

  • XAL5030-332MEC

    3.3 µH ±20% · DCR max: 23.3 mΩ

    Overall envelope including tolerances and terminals: 5.68 × 5.48 × 3.1 mm

    Source temperature range: -40…125°C (ambient with rated rise)

    Required peak
    3.45 A
    Required RMS
    3.0112 A
    Recalculated ripple
    0.9 A

    Published Isat / L drop: 8.7 A / 30% · 25°C

    Published Irms / rise / ambient: 8.1 A / 40°C / 25°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture

    Original source: XAL50xx · Document 908 · 02/26/26 · Source checked:

  • SRP5030TA-3R3M

    3.3 µH ±20% · DCR max: 38 mΩ

    Overall envelope including tolerances and terminals: 6 × 5.4 × 3 mm

    Source temperature range: -55…150°C (component including rise)

    Required peak
    3.45 A
    Required RMS
    3.0112 A
    Recalculated ripple
    0.9 A

    Published Isat / L drop: 8 A / 20% · 25°C

    Published Irms / rise / ambient: 5 A / 40°C / —°C

    Missing evidence: DC-bias curve points · Thermal test PCB / fixture · Thermal ambient / rise conditions · Saturation criterion / temperature · Inductance test conditions

    Original source: SRP5030TA · 11/19 · Source checked:

Compare test conditions →

Model & formulas

Isat is defined at a manufacturer-specific inductance drop; thermal ratings depend on permitted temperature rise and test setup. Headroom is (rating − demand) / rating. A within-rating result is conditional, not a complete design approval. Startup/fault peak affects the saturation check only.

Ipeak = Iavg + ΔI/2

Irms = √(Iavg² + ΔI²/12)

Technical references

Questions, examples and engineering limits

Calculate triangular-ripple peak and RMS current, then compare saturation and thermal limits. Understand rating conditions and required margin.

Content updated:

How is Inductor Current Check: Peak, RMS, Isat and Irms calculated?

Use Ipeak = Iavg + ΔIpp/2; Irms = √(Iavg² + ΔIpp²/12). Calculate triangular-ripple peak and RMS current, then compare saturation and thermal limits. Understand rating conditions and required margin.

Sources: coilcraft.com [1]

How do I calculate this example: Iavg = 2 A, ΔIpp = 0.6 A?

Ipeak = 2.3 A; Irms ≈ 2.007486 A. This is a calculated example under the model stated above; it is not a measured component specification.

Which units does Inductor Current Check: Peak, RMS, Isat and Irms use?

A, mA, %. Convert prefixes before substituting values; keep the input and output units attached to every number.

Sources: coilcraft.com [1]

Are saturation current and RMS current interchangeable?

No. Compare peak current with the specified saturation criterion and RMS current with the thermal rating under its test conditions.

Sources: coilcraft.com [1]

Is nominal inductance constant at every current?

No. DC bias, temperature and measurement frequency can change inductance. Use the manufacturer’s curves for the selected part rather than assuming a constant value.

Sources: coilcraft.com [1]

Can this result predict temperature rise?

No. Temperature rise also requires loss data, mounting, airflow and a validated thermal model. A calculated electrical value is not a thermal qualification.

Sources: coilcraft.com [1]

Answers use the stated model and units. Examples are calculated values, not measurements or component ratings.