Magnetic Core AL Database
Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.
Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.
Toroid calculator →Matching catalogue records: 6420 / 6420
| Model | Material | AL (nH/N²) | OD × ID × H (mm) | AL tolerance | Manufacturer source | Toroid calculator |
|---|---|---|---|---|---|---|
| KDA KPH185-040A | KPH 40 μ | 57 | 47.63 × 27.89 × 16.13 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH185-060A | KPH 60 μ | 86 | 47.63 × 27.89 × 16.13 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH200-026A | KPH 26 μ | 32 | 51.69 × 30.94 × 14.35 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH200-040A | KPH 40 μ | 48 | 51.69 × 30.94 × 14.35 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH200-060A | KPH 60 μ | 73 | 51.69 × 30.94 × 14.35 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH225-026A | KPH 26 μ | 33 | 58 × 34.7 × 14.86 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH225-040A | KPH 40 μ | 50 | 58 × 34.7 × 14.86 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH225-060A | KPH 60 μ | 75 | 58 × 34.7 × 14.86 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH226-026A | KPH 26 μ | 60 | 58 × 25.6 × 16.1 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH226-040A | KPH 40 μ | 92 | 58 × 25.6 × 16.1 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH226-060A | KPH 60 μ | 138 | 58 × 25.6 × 16.1 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH250-026A | KPH 26 μ | 83 | 63.1 × 31.37 × 26.27 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH250-040A | KPH 40 μ | 128 | 63.1 × 31.37 × 26.27 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH250-060A | KPH 60 μ | 192 | 63.1 × 31.37 × 26.27 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH268-026A | KPH 26 μ | 62 | 69.4 × 34.7 × 21.4 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH268-040A | KPH 40 μ | 95 | 69.4 × 34.7 × 21.4 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH268-060A | KPH 60 μ | 143 | 69.4 × 34.7 × 21.4 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH300-026A | KPH 26 μ | 30 | 78.9 × 48.2 × 13.84 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH300-040A | KPH 40 μ | 45 | 78.9 × 48.2 × 13.84 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH300-060A | KPH 60 μ | 68 | 78.9 × 48.2 × 13.84 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH301-026A | KPH 26 μ | 37 | 78.9 × 48.2 × 17.02 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH301-040A | KPH 40 μ | 56 | 78.9 × 48.2 × 17.02 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH301-060A | KPH 60 μ | 85 | 78.9 × 48.2 × 17.02 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH400-026A | KPH 26 μ | 48 | 103.12 × 55.75 × 17.78 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH400-040A | KPH 40 μ | 74 | 103.12 × 55.75 × 17.78 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KPH400-060A | KPH 60 μ | 112 | 103.12 × 55.75 × 17.78 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF050-026A | KSF 26 μ | 12 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF050-060A | KSF 60 μ | 27 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF050-075A | KSF 75 μ | 34 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF050-090A | KSF 90 μ | 40 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF065-026A | KSF 26 μ | 15 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF065-060A | KSF 60 μ | 35 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF065-075A | KSF 75 μ | 43 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF065-090A | KSF 90 μ | 52 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF068-026A | KSF 26 μ | 19 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF068-060A | KSF 60 μ | 43 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF068-075A | KSF 75 μ | 53 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF068-090A | KSF 90 μ | 64 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF080-026A | KSF 26 μ | 14 | 21.1 × 12.07 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KSF080-060A | KSF 60 μ | 32 | 21.1 × 12.07 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
Engineering questions
Does AL remain constant under DC bias?
No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.
Why can 20 turns fall short of the target inductance?
N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.
Will a larger wire diameter still fit?
Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.