Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OE-133075-2
OE - Optimized Economy 75 μ10033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-133090-2
SP - SenPreum™ 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-133090-2
OC - Optimized Core Loss 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-133090-2
HF - Hi-Flux™ 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-133090-2
MS - Sendust 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-133090-2
OE - Optimized Economy 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-133090-2
FX 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-133090-2
SM - SenMax™ 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-133090-2
OD - Optimized DC Bias 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-133090-2
FS - FluxSan™ 90 μ12033.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-133125-2
OC - Optimized Core Loss 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-133125-2
HF - Hi-Flux™ 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-133125-2
MS - Sendust 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-133125-2
FX 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-133125-2
SM - SenMax™ 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-133125-2
FS - FluxSan™ 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-133125-2
HFP 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-133125-2
MP - MPP 125 μ166.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-133147-2
MP - MPP 147 μ19633.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-133147-2
HF - Hi-Flux™ 147 μ19633.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-133147-2
MS - Sendust 147 μ19633.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-133160-2
MP - MPP 160 μ21333.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-133160-2
HF - Hi-Flux™ 160 μ21333.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-133160-2
MS - Sendust 160 μ21333.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-133173-2
MP - MPP 173 μ230.69999733.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-133205-2
MP - MPP 205 μ266.70001233.02 × 19.94 × 14Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-134014-2
FX 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-134014-2
SM - SenMax™ 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-134014-2
MP - MPP 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-134014-2
HF - Hi-Flux™ 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-134014-2
FS - FluxSan™ 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-134014-2
MS - Sendust 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-134014-2
SP - SenPreum™ 14 μ23.79999933.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-134026-2
OE - Optimized Economy 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-134026-2
OD - Optimized DC Bias 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-134026-2
SP - SenPreum™ 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-134026-2
FX 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-134026-2
SM - SenMax™ 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-134026-2
OC - Optimized Core Loss 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-134026-2
MP - MPP 26 μ4433.02 × 19.94 × 18Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.