My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
MS-159147-2
MS - Sendust 147 μ30840.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-159160-2
HF - Hi-Flux™ 160 μ33540.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-159160-2
MS - Sendust 160 μ33540.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-159160-2
MP - MPP 160 μ33540.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-159173-2
MP - MPP 173 μ36240.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-159205-2
MP - MPP 205 μ43040.5 × 17.5 × 13.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170014-2
FX 14 μ31.543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170014-2
MS - Sendust 14 μ31.543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170026-2
FX 26 μ5843.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170026-2
MS - Sendust 26 μ5843.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170040-2
MS - Sendust 40 μ9043.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170040-2
FX 40 μ9043.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170060-2
FX 60 μ13543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-170060-2
HFP 60 μ13543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170060-2
MS - Sendust 60 μ13543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-170060-2
GX - Alloy 60 μ13543.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170075-2
FX 75 μ16943.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170075-2
MS - Sendust 75 μ16943.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170090-2
MS - Sendust 90 μ20343.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-170090-2
FX 90 μ20343.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-170125-2
HFP 125 μ28143.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170125-2
MS - Sendust 125 μ28143.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170147-2
MS - Sendust 147 μ33143.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-170160-2
MS - Sendust 160 μ36043.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-170173-2
MP - MPP 173 μ39043.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-170205-2
MP - MPP 205 μ46143.2 × 18.6 × 14.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-171014-2
MP - MPP 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-171014-2
FS - FluxSan™ 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-171014-2
FX 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-171014-2
SM - SenMax™ 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-171014-2
SP - SenPreum™ 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-171014-2
MS - Sendust 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-171014-2
HF - Hi-Flux™ 14 μ2143.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-171026-2
FX 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-171026-2
SM - SenMax™ 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-171026-2
SP - SenPreum™ 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-171026-2
MS - Sendust 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-171026-2
HF - Hi-Flux™ 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-171026-2
OD - Optimized DC Bias 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-171026-2
MP - MPP 26 μ4043.4 × 26.4 × 16.2Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources