My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OC-200125-2
OC - Optimized Core Loss 125 μ15250.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-200125-2
MS - Sendust 125 μ15250.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-200125-2
HF - Hi-Flux™ 125 μ15250.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-200125-2
MP - MPP 125 μ15250.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-200125-2
HFP 125 μ15250.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-200147-2
MS - Sendust 147 μ17950.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-200147-2
HF - Hi-Flux™ 147 μ17950.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-200147-2
MP - MPP 147 μ17950.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-200160-2
MS - Sendust 160 μ19550.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-200160-2
HF - Hi-Flux™ 160 μ19550.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-200160-2
MP - MPP 160 μ19550.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-200173-2
MP - MPP 173 μ21050.8 × 31.75 × 13.46Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-6
-6 8.5 μ10.450.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-7
-7 9 μ10.550.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-2
-2 10 μ1250.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-1
-1 20 μ2550.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-35
-35 33 μ3750.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-34
-34 33 μ3750.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-8/90
-8 35 μ42.550.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-3
-3 35 μ42.550.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-60
-60 55 μ6750.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-18
-18 55 μ6750.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-19
-19 55 μ6750.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-40
-40 60 μ7950.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-66
-66 66 μ8050.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-52
-52 75 μ9250.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-26
-26 75 μ9250.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-38
-38 85 μ10450.8 × 31.75 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-8C/90
-8 35 μ5750.8 × 31.75 × 19.05Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-26C
-26 75 μ12250.8 × 31.75 × 19.05Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-199014-2
FS - FluxSan™ 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-199014-2
SM - SenMax™ 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-199014-2
SP - SenPreum™ 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-199014-2
MS - Sendust 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199014-2
HF - Hi-Flux™ 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199014-2
MP - MPP 14 μ4150.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-199026-2
SP - SenPreum™ 26 μ7650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-199026-2
MS - Sendust 26 μ7650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199026-2
HF - Hi-Flux™ 26 μ7650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199026-2
MP - MPP 26 μ7650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources