Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
MS-199090-2
MS - Sendust 90 μ26350.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199090-2
HF - Hi-Flux™ 90 μ26350.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-199125-2
OC - Optimized Core Loss 125 μ36650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-199125-2
HFP 125 μ36650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199125-2
MP - MPP 125 μ36650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-199125-2
MS - Sendust 125 μ36650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199125-2
HF - Hi-Flux™ 125 μ36650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199147-2
MP - MPP 147 μ43050.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-199147-2
MS - Sendust 147 μ43050.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199147-2
HF - Hi-Flux™ 147 μ43050.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199160-2
MP - MPP 160 μ46850.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-199160-2
MS - Sendust 160 μ46850.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-199160-2
HF - Hi-Flux™ 160 μ46850.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-199173-2
MP - MPP 173 μ50650.8 × 24.77 × 20.83Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-0
-0 1 μ4.250.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-8/90
-8 35 μ10450.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-18
-18 55 μ16450.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-40
-40 60 μ19450.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-26
-26 75 μ22450.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T201-52
-52 75 μ22450.8 × 24.13 × 22.23Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-2B
-2 10 μ21.79999950.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-30B
-30 22 μ5150.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-35B
-35 33 μ7450.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-8B/90
-8 35 μ78.550.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-3B
-3 35 μ78.550.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-18B
-18 55 μ12050.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-19B
-19 55 μ12050.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-60B
-60 55 μ12050.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-40B
-40 60 μ14250.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-66B
-66 66 μ14550.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-26B
-26 75 μ16050.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-52B
-52 75 μ15550.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T200-38B
-38 85 μ18050.8 × 31.75 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-17
-17 4 μ557.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-10
-10 6 μ7.557.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-6
-6 8.5 μ10.457.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-2
-2 10 μ1257.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-30
-30 22 μ2857.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-34
-34 33 μ3757.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-35
-35 33 μ3757.15 × 35.69 × 13.97Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.