My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OC-226075-2
OC - Optimized Core Loss 75 μ17257.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-226090-2
OC - Optimized Core Loss 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-226090-2
OD - Optimized DC Bias 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-226090-2
FS - FluxSan™ 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-226090-2
SM - SenMax™ 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-226090-2
OE - Optimized Economy 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-226090-2
SP - SenPreum™ 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-226090-2
MS - Sendust 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-226090-2
HF - Hi-Flux™ 90 μ20757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-226125-2
HFP 125 μ28757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-226125-2
MS - Sendust 125 μ28757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-226125-2
HF - Hi-Flux™ 125 μ28757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-226125-2
OC - Optimized Core Loss 125 μ28757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-226125-2
MP - MPP 125 μ28757.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-226147-2
MP - MPP 147 μ33857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-226147-2
MS - Sendust 147 μ33857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-226147-2
HF - Hi-Flux™ 147 μ33857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-226160-2
MP - MPP 160 μ36857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-226160-2
MS - Sendust 160 μ36857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-226160-2
HF - Hi-Flux™ 160 μ36857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-226173-2
MP - MPP 173 μ39857.15 × 26.39 × 15.24Not recordedManufacturer sourceCalculate with this core →
Micrometals
T224-52C
-52 75 μ15557.15 × 31.75 × 19.05Not recordedManufacturer sourceCalculate with this core →
Micrometals
T224-26C
-26 75 μ15557.15 × 31.75 × 19.05Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-6B
-6 8.5 μ18.557.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-2B
-2 10 μ21.557.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-14B
-14 14 μ2857.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-34B
-34 33 μ6757.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-60B
-60 55 μ12057.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-66B
-66 66 μ14557.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-52B
-52 75 μ15557.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-26B
-26 75 μ16057.15 × 35.69 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T225-34D
-34 33 μ7457.15 × 35.69 × 27.94Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-226014-2H305
MP - MPP 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-226014-2H305
FS - FluxSan™ 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-226014-2H305
SM - SenMax™ 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-226014-2H305
MS - Sendust 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-226014-2H305
SP - SenPreum™ 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-226014-2H305
HF - Hi-Flux™ 14 μ6457.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-226026-2H305
SM - SenMax™ 26 μ12057.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-226026-2H305
OD - Optimized DC Bias 26 μ12057.15 × 26.39 × 30.48Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources