Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OD-306060-2
OD - Optimized DC Bias 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-306060-2
MP - MPP 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-306060-2
SM - SenMax™ 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-306060-2
FS - FluxSan™ 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-306060-2
GX - Alloy 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-306060-2
MS - Sendust 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-306060-2
OE - Optimized Economy 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-306060-2
OC - Optimized Core Loss 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-306060-2
SP - SenPreum™ 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-306060-2
HFP 60 μ20577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-306075-2
SM - SenMax™ 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-306075-2
FS - FluxSan™ 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-306075-2
MS - Sendust 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-306075-2
OE - Optimized Economy 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-306075-2
OC - Optimized Core Loss 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-306075-2
SP - SenPreum™ 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-306075-2
HF - Hi-Flux™ 75 μ25577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-306090-2
OE - Optimized Economy 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-306090-2
OC - Optimized Core Loss 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-306090-2
SP - SenPreum™ 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-306090-2
HF - Hi-Flux™ 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-306090-2
OD - Optimized DC Bias 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-306090-2
FS - FluxSan™ 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-306090-2
MS - Sendust 90 μ30677.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-306125-2
HF - Hi-Flux™ 125 μ42577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-306125-2
MS - Sendust 125 μ42577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-306125-2
OC - Optimized Core Loss 125 μ42577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-306125-2
MP - MPP 125 μ42577.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-306147-2
MS - Sendust 147 μ50077.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-306147-2
MP - MPP 147 μ50077.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-306147-2
HF - Hi-Flux™ 147 μ50077.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-306160-2
MP - MPP 160 μ54477.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-306173-2
MP - MPP 173 μ61177.8 × 39.34 × 25.85Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-350014-2
HF - Hi-Flux™ 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-350014-2
FS - FluxSan™ 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-350014-2
MP - MPP 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-350014-2
SM - SenMax™ 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-350014-2
SP - SenPreum™ 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-350014-2
MS - Sendust 14 μ1388.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-350026-2
HF - Hi-Flux™ 26 μ2488.85 × 66.01 × 15.93Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.