Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
T400-66
-66 66 μ114101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-400075-2
OE - Optimized Economy 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-400075-2
OC - Optimized Core Loss 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-52
-52 75 μ131101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-400075-2
SM - SenMax™ 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-400075-2
SP - SenPreum™ 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-400075-2
MS - Sendust 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-26
-26 75 μ131101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-400075-2
FS - FluxSan™ 75 μ137101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-400090-2
OD - Optimized DC Bias 90 μ164101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-400090-2
MS - Sendust 90 μ164101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-400090-2
FS - FluxSan™ 90 μ164101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-400090-2
OE - Optimized Economy 90 μ164101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-400090-2
OC - Optimized Core Loss 90 μ164101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-400125-2
MS - Sendust 125 μ228101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-400125-2
MP - MPP 125 μ228101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-400125-2
OC - Optimized Core Loss 125 μ228101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-400125-2
HF - Hi-Flux™ 125 μ228101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-400147-2
MS - Sendust 147 μ268101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-400147-2
MP - MPP 147 μ268101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-400160-2
MP - MPP 160 μ282101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-400173-2
MP - MPP 173 μ316101.6 × 57.15 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-35B
-35 33 μ89101.6 × 57.15 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-26B
-26 75 μ205101.6 × 57.15 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-0D
-0 1 μ4.8101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-17D
-17 4 μ14.4101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-6D
-6 8.5 μ30.5101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-2D
-2 10 μ36101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-14D
-14 14 μ45.5101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-30D
-30 22 μ81101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-35D
-35 33 μ110101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-34D
-34 33 μ110101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-63D
-63 35 μ120101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-61D
-61 38 μ120101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-60D
-60 55 μ192101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-40D
-40 60 μ230101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-66D
-66 66 μ228101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-52D
-52 75 μ262101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
T400-26D
-26 75 μ262101.6 × 57.15 × 33.02Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-456060-2
MS - Sendust 60 μ106115.92 × 77.02 × 22Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.