My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
HF-520060-2
HF - Hi-Flux™ 60 μ124132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-520060-2
OD - Optimized DC Bias 60 μ124132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-520060-2
SM - SenMax™ 60 μ124132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-520060-2
OE - Optimized Economy 60 μ124132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-520075-2
OC - Optimized Core Loss 75 μ155132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-520075-2
MS - Sendust 75 μ155132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-520075-2
FS - FluxSan™ 75 μ155132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-520090-2
HF - Hi-Flux™ 90 μ187132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-520090-2
MS - Sendust 90 μ187132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-520125-2
MS - Sendust 125 μ259132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-520125-2
MP - MPP 125 μ259132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-520125-2
OC - Optimized Core Loss 125 μ259132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-520125-2
HF - Hi-Flux™ 125 μ259132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-520147-2
MP - MPP 147 μ304132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-520160-2
MP - MPP 160 μ332132.54 × 78.59 × 20.32Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-521014-2
SM - SenMax™ 14 μ36.400002132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-521014-2
FS - FluxSan™ 14 μ36.400002132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-521014-2
HF - Hi-Flux™ 14 μ36.400002132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-521014-2
MP - MPP 14 μ36.400002132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-521014-2
MS - Sendust 14 μ36.400002132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-521026-2
FS - FluxSan™ 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-521026-2
HF - Hi-Flux™ 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-521026-2
MP - MPP 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-521026-2
OD - Optimized DC Bias 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-521026-2
MS - Sendust 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-521026-2
OC - Optimized Core Loss 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-521026-2
OE - Optimized Economy 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-521026-2
SP - SenPreum™ 26 μ67.599998132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-521040-2
OC - Optimized Core Loss 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-521040-2
SM - SenMax™ 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-521040-2
OE - Optimized Economy 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-521040-2
FS - FluxSan™ 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-521040-2
MP - MPP 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-521040-2
OD - Optimized DC Bias 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-521040-2
MS - Sendust 40 μ104132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-521060-2
FS - FluxSan™ 60 μ156132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-521060-2
SP - SenPreum™ 60 μ156132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-521060-2
MP - MPP 60 μ156132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-521060-2
OD - Optimized DC Bias 60 μ156132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-521060-2
MS - Sendust 60 μ156132.54 × 78.59 × 25.4Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources