My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
MS-038014-8
MS - Sendust 14 μ79.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-038026-8
FS - FluxSan™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-038026-8
SP - SenPreum™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-038026-8
MS - Sendust 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-038026-8
OD - Optimized DC Bias 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-038026-2
OE - Optimized Economy 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-038026-8
OC - Optimized Core Loss 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-038026-2
FS - FluxSan™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-038026-2
SP - SenPreum™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-038026-8
SM - SenMax™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-038026-2
MS - Sendust 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-038026-8
MP - MPP 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-038026-8
HF - Hi-Flux™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-038026-2
OC - Optimized Core Loss 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-038026-2
OD - Optimized DC Bias 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-038026-2
SM - SenMax™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-038026-2
MP - MPP 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-038026-2
HF - Hi-Flux™ 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-038026-8
OE - Optimized Economy 26 μ149.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-038040-2
OC - Optimized Core Loss 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-038040-2
SM - SenMax™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-038040-8
OE - Optimized Economy 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-038040-8
FS - FluxSan™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-038040-8
SP - SenPreum™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-038040-8
MS - Sendust 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-038040-2
OE - Optimized Economy 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-038040-8
OD - Optimized DC Bias 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-038040-2
FS - FluxSan™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-038040-2
SP - SenPreum™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-038040-8
SM - SenMax™ 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-038040-2
MS - Sendust 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-038040-2
OD - Optimized DC Bias 40 μ219.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-038060-8
OD - Optimized DC Bias 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-038060-2
FS - FluxSan™ 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-038060-2
SP - SenPreum™ 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-038060-8
SM - SenMax™ 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-038060-2
MS - Sendust 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-038060-2
MP - MPP 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-038060-2
HF - Hi-Flux™ 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-038060-8
OC - Optimized Core Loss 60 μ329.65 × 4.78 × 3.96Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources