My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OE-050040-2H095
OE - Optimized Economy 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-050040-2H095
SM - SenMax™ 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-050040-2H095
OD - Optimized DC Bias 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-050040-2H095
OC - Optimized Core Loss 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-050040-2H095
MP - MPP 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050040-2H095
MS - Sendust 40 μ3612.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-050060-2H095
OC - Optimized Core Loss 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-050060-2H095
MP - MPP 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050060-2H095
MS - Sendust 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-050060-2H095
SP - SenPreum™ 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-050060-2H095
HF - Hi-Flux™ 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-050060-2H095
HFP 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-050060-2H095
OE - Optimized Economy 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-050060-2H095
FS - FluxSan™ 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-050060-2H095
SM - SenMax™ 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-050060-2H095
OD - Optimized DC Bias 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-050060-2H095
GX - Alloy 60 μ5412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-050075-2H095
SM - SenMax™ 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-050075-2H095
OC - Optimized Core Loss 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050075-2H095
MS - Sendust 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-050075-2H095
SP - SenPreum™ 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-050075-2H095
OE - Optimized Economy 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-050075-2H095
FS - FluxSan™ 75 μ6812.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-050090-2H095
SP - SenPreum™ 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-050090-2H095
OD - Optimized DC Bias 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-050090-2H095
OE - Optimized Economy 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-050090-2H095
FS - FluxSan™ 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-050090-2H095
OC - Optimized Core Loss 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050090-2H095
MS - Sendust 90 μ8012.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-050125-2H095
SM - SenMax™ 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-050125-2H095
HF - Hi-Flux™ 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050125-2H095
MS - Sendust 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-050125-2H095
MP - MPP 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-050125-2H095
FS - FluxSan™ 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-050125-2H095
HFP 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-050125-2H095
OC - Optimized Core Loss 125 μ11212.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-050147-2H095
HF - Hi-Flux™ 147 μ13412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-050147-2H095
MS - Sendust 147 μ13412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-050147-2H095
MP - MPP 147 μ13412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-050160-2H095
MP - MPP 160 μ14412.7 × 7.62 × 9.5Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources