My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
MS-068125-2
MS - Sendust 125 μ8917.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068125-2
MP - MPP 125 μ8917.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-068125-2
FS - FluxSan™ 125 μ8917.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-068147-2
HF - Hi-Flux™ 147 μ10517.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068147-2
MS - Sendust 147 μ10517.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068147-2
MP - MPP 147 μ10517.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068160-2
MP - MPP 160 μ11417.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-068160-2
HF - Hi-Flux™ 160 μ11417.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068160-2
MS - Sendust 160 μ11417.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068173-2
MP - MPP 173 μ12317.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068205-2
MP - MPP 205 μ14617.27 × 9.65 × 6.35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068014-2H127
MS - Sendust 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-068014-2H127
SP - SenPreum™ 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-068014-2H127
SM - SenMax™ 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-068014-2H127
FS - FluxSan™ 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068014-2H127
MP - MPP 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-068014-2H127
HF - Hi-Flux™ 14 μ2017.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-068026-2H127
OD - Optimized DC Bias 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068026-2H127
MP - MPP 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-068026-2H127
OC - Optimized Core Loss 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-068026-2H127
HF - Hi-Flux™ 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-068026-2H127
FX 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068026-2H127
MS - Sendust 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-068026-2H127
SM - SenMax™ 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-068026-2H127
SP - SenPreum™ 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-068026-2H127
FS - FluxSan™ 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-068026-2H127
OE - Optimized Economy 26 μ3817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-068040-2H127
FS - FluxSan™ 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-068040-2H127
OE - Optimized Economy 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-068040-2H127
OD - Optimized DC Bias 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-068040-2H127
OC - Optimized Core Loss 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-068040-2H127
MP - MPP 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068040-2H127
MS - Sendust 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-068040-2H127
SP - SenPreum™ 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-068040-2H127
SM - SenMax™ 40 μ5817.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-068060-2H127
MS - Sendust 60 μ8617.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-068060-2H127
SP - SenPreum™ 60 μ8617.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-068060-2H127
SM - SenMax™ 60 μ8617.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-068060-2H127
HF - Hi-Flux™ 60 μ8617.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-068060-2H127
FS - FluxSan™ 60 μ8617.27 × 9.65 × 12.7Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources