Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
KDA
KS268-026A-HF
KS-HF 26 μ6269.4 × 34.7 × 21.4Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS268-060A-HF
KS-HF 60 μ14369.4 × 34.7 × 21.4Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS268-075A-HF
KS-HF 75 μ17969.4 × 34.7 × 21.4Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS268-090A-HF
KS-HF 90 μ21469.4 × 34.7 × 21.4Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS290-026A-HF
KS-HF 26 μ8975.2 × 44.07 × 36.27Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS290-060A-HF
KS-HF 60 μ20675.2 × 44.07 × 36.27Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS290-075A-HF
KS-HF 75 μ25775.2 × 44.07 × 36.27Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS290-090A-HF
KS-HF 90 μ30975.2 × 44.07 × 36.27Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS300-026A-HF
KS-HF 26 μ3078.9 × 48.2 × 13.84Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS300-060A-HF
KS-HF 60 μ6878.9 × 48.2 × 13.84Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS300-075A-HF
KS-HF 75 μ8578.9 × 48.2 × 13.84Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS300-090A-HF
KS-HF 90 μ10278.9 × 48.2 × 13.84Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS301-026A-HF
KS-HF 26 μ3778.9 × 48.2 × 17.02Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS301-060A-HF
KS-HF 60 μ8578.9 × 48.2 × 17.02Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS301-075A-HF
KS-HF 75 μ10778.9 × 48.2 × 17.02Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS301-090A-HF
KS-HF 90 μ12878.9 × 48.2 × 17.02Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS400-026A-HF
KS-HF 26 μ48103.12 × 55.75 × 17.78Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS400-060A-HF
KS-HF 60 μ112103.12 × 55.75 × 17.78Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS400-075A-HF
KS-HF 75 μ137103.12 × 55.75 × 17.78Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS400-090A-HF
KS-HF 90 μ164103.12 × 55.75 × 17.78Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS401-026A-HF
KS-HF 26 μ40103.12 × 55.75 × 14.86Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS401-060A-HF
KS-HF 60 μ92103.12 × 55.75 × 14.86Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS401-075A-HF
KS-HF 75 μ115103.12 × 55.75 × 14.86Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS401-090A-HF
KS-HF 90 μ139103.12 × 55.75 × 14.86Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS520-026A-HF
KS-HF 26 μ54133.96 × 77.04 × 21.72Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS520-060A-HF
KS-HF 60 μ124133.96 × 77.04 × 21.72Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS521-026A-HF
KS-HF 26 μ68133.96 × 77.04 × 26.8Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KS521-060A-HF
KS-HF 60 μ156133.96 × 77.04 × 26.8Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH050-026A
KPH 26 μ1213.46 × 6.99 × 5.51Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH050-040A
KPH 40 μ1813.46 × 6.99 × 5.51Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH050-060A
KPH 60 μ2713.46 × 6.99 × 5.51Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH065-026A
KPH 26 μ1517.4 × 9.53 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH065-040A
KPH 40 μ2317.4 × 9.53 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH065-060A
KPH 60 μ3517.4 × 9.53 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH068-026A
KPH 26 μ1918.03 × 9.02 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH068-040A
KPH 40 μ2818.03 × 9.02 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH068-060A
KPH 60 μ4318.03 × 9.02 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH080-026A
KPH 26 μ1421.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH080-040A
KPH 40 μ2121.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KPH080-060A
KPH 60 μ3221.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources