Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
OE-080040-2H127
OE - Optimized Economy 40 μ4220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-080060-2H127
SP - SenPreum™ 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-080060-2H127
OE - Optimized Economy 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-080060-2H127
HF - Hi-Flux™ 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-080060-2H127
HFP 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-080060-2H127
GX - Alloy 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-080060-2H127
SM - SenMax™ 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-080060-2H127
FS - FluxSan™ 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080060-2H127
MP - MPP 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-080060-2H127
OC - Optimized Core Loss 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080060-2H127
MS - Sendust 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-080060-2H127
OD - Optimized DC Bias 60 μ6420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-080075-2H127
OC - Optimized Core Loss 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080075-2H127
MS - Sendust 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-080075-2H127
SP - SenPreum™ 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-080075-2H127
OE - Optimized Economy 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-080075-2H127
SM - SenMax™ 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-080075-2H127
FS - FluxSan™ 75 μ8220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-080090-2H127
SM - SenMax™ 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-080090-2H127
OD - Optimized DC Bias 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-080090-2H127
FS - FluxSan™ 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-080090-2H127
OC - Optimized Core Loss 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080090-2H127
MS - Sendust 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-080090-2H127
SP - SenPreum™ 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-080090-2H127
OE - Optimized Economy 90 μ9820.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080125-2H127
MP - MPP 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-080125-2H127
SM - SenMax™ 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-080125-2H127
HFP 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-080125-2H127
FS - FluxSan™ 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-080125-2H127
OC - Optimized Core Loss 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-080125-2H127
HF - Hi-Flux™ 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080125-2H127
MS - Sendust 125 μ13620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-080147-2H127
HF - Hi-Flux™ 147 μ16220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080147-2H127
MS - Sendust 147 μ16220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080147-2H127
MP - MPP 147 μ16220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-080160-2H127
HF - Hi-Flux™ 160 μ17420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-080160-2H127
MS - Sendust 160 μ17420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080160-2H127
MP - MPP 160 μ17420.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080173-2H127
MP - MPP 173 μ19220.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-080205-2H127
MP - MPP 205 μ22620.32 × 12.7 × 12.7Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.