My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
HF-090075-2
HF - Hi-Flux™ 75 μ5422.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-090075-2
SM - SenMax™ 75 μ5422.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-090075-2
MS - Sendust 75 μ5422.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-090075-2
FS - FluxSan™ 75 μ5422.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-090090-2
OE - Optimized Economy 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-090090-2
HF - Hi-Flux™ 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-090090-2
SM - SenMax™ 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-090090-2
MS - Sendust 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-090090-2
FS - FluxSan™ 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-090090-2
SP - SenPreum™ 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-090090-2
OD - Optimized DC Bias 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-090090-2
OC - Optimized Core Loss 90 μ6522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-090125-2
SM - SenMax™ 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-090125-2
HF - Hi-Flux™ 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-090125-2
MS - Sendust 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-090125-2
FS - FluxSan™ 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-090125-2
MP - MPP 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-090125-2
OC - Optimized Core Loss 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-M125E
-M125 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-090125-2
HFP 125 μ9022.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-090147-2
MP - MPP 147 μ10622.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-090147-2
HF - Hi-Flux™ 147 μ10622.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-090147-2
MS - Sendust 147 μ10622.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-090160-2
HF - Hi-Flux™ 160 μ11522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-090160-2
MS - Sendust 160 μ11522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-090160-2
MP - MPP 160 μ11522.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-090173-2
MP - MPP 173 μ12422.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-090205-2
MP - MPP 205 μ14722.86 × 13.97 × 7.62Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-8/90
-8 35 μ3022.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-60
-60 55 μ4722.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-19
-19 55 μ4722.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-18
-18 55 μ4722.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-40
-40 60 μ5722.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-66
-66 66 μ5622.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-52
-52 75 μ6422.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-26
-26 75 μ7022.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-38
-38 85 μ7322.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-70
-70 100 μ8522.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
T90-45
-45 100 μ8522.86 × 13.97 × 9.53Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-092014-2
MS - Sendust 14 μ1223.57 × 14.4 × 8.89Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources