LogoMagdir

Inductor Current Check

Check peak and RMS inductor currents against saturation and thermal ratings, with explicit datasheet conditions.

Calculations run locally. Save is device-only; sharing includes the entered values.

Operating conditions

Units are fixed beside each field: V, A, kHz, µH, mΩ and °C.

A
A

Use DC or a nonnegative continuous triangular current. For nonzero ripple, average current must exceed half the peak-to-peak ripple. Pulsed/DCM and reverse-current waveforms require another model.

A
A
A

Calculation results

Peak current
3.45 A
RMS current
3.0112 A
Peak used for saturation check
3.45 A

Saturation current Isat (optional)

Conditions/data incomplete

Rating headroom: —%

Thermal current rating (optional)

Conditions/data incomplete

Rating headroom: —%

Review both rating conditions before using the result.

Estimate copper loss →

Model & formulas

Isat is defined at a manufacturer-specific inductance drop; thermal ratings depend on permitted temperature rise and test setup. Headroom is (rating − demand) / rating. A within-rating result is conditional, not a complete design approval. Startup/fault peak affects the saturation check only.

Ipeak = Iavg + ΔI/2

Irms = √(Iavg² + ΔI²/12)

Technical references