My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
T157-34
-34 33 μ43.539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-3
-3 35 μ4239.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-63
-63 35 μ4539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-8/90
-8 35 μ4239.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-19
-19 55 μ7339.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-60
-60 55 μ7339.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-18
-18 55 μ7339.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-40
-40 60 μ8639.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-66
-66 66 μ8739.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-52
-52 75 μ9939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-26
-26 75 μ10039.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-38
-38 85 μ11239.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-45
-45 100 μ13039.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-70
-70 100 μ13039.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
T157-26B
-26 75 μ12239.88 × 24.13 × 18.03Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-157014-2
FS - FluxSan™ 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-157014-2
MS - Sendust 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-157014-2
OC - Optimized Core Loss 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-157014-2
SP - SenPreum™ 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-157014-2
FX 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-157014-2
SM - SenMax™ 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-157014-2
MP - MPP 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-157014-2
HF - Hi-Flux™ 14 μ1939.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-157026-2
OE - Optimized Economy 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-157026-2
OC - Optimized Core Loss 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-157026-2
SP - SenPreum™ 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-157026-2
OD - Optimized DC Bias 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-157026-2
FX 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-157026-2
SM - SenMax™ 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-157026-2
MP - MPP 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-157026-2
HF - Hi-Flux™ 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-157026-2
FS - FluxSan™ 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-157026-2
MS - Sendust 26 μ3539.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-157040-2
OD - Optimized DC Bias 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-157040-2
FX 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-157040-2
SM - SenMax™ 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-157040-2
MP - MPP 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-157040-2
HF - Hi-Flux™ 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-157040-2
FS - FluxSan™ 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-157040-2
MS - Sendust 40 μ5439.88 × 24.13 × 14.48Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources