My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
SP-268060-2
SP - SenPreum™ 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-268060-2
GX - Alloy 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-268060-2
HF - Hi-Flux™ 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-268060-2
SM - SenMax™ 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-268060-2
HFP 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-268060-2
MP - MPP 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-268060-2
OE - Optimized Economy 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-268060-2
OD - Optimized DC Bias 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-268060-2
FS - FluxSan™ 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-268060-2
MS - Sendust 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-268060-2
FX 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-268060-2
OC - Optimized Core Loss 60 μ14368 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-268075-2
OE - Optimized Economy 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-268075-2
FS - FluxSan™ 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-268075-2
MS - Sendust 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-268075-2
OC - Optimized Core Loss 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-268075-2
SP - SenPreum™ 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-268075-2
HF - Hi-Flux™ 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-268075-2
SM - SenMax™ 75 μ18768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-268090-2
OD - Optimized DC Bias 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-268090-2
OC - Optimized Core Loss 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-268090-2
SP - SenPreum™ 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-268090-2
HF - Hi-Flux™ 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-268090-2
SM - SenMax™ 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-268090-2
OE - Optimized Economy 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-268090-2
FS - FluxSan™ 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-268090-2
MS - Sendust 90 μ22568 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-268125-2
HF - Hi-Flux™ 125 μ31268 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-268125-2
MS - Sendust 125 μ31268 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-268125-2
OC - Optimized Core Loss 125 μ31268 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-268125-2
MP - MPP 125 μ31268 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-268147-2
MS - Sendust 147 μ36768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-268147-2
MP - MPP 147 μ36768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-268147-2
HF - Hi-Flux™ 147 μ36768 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-268160-2
MP - MPP 160 μ40068 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-268173-2
MP - MPP 173 μ48268 × 36 × 20Not recordedManufacturer sourceCalculate with this core →
Micrometals
T270-40D
-40 60 μ18768.45 × 40.39 × 26.8Not recordedManufacturer sourceCalculate with this core →
Micrometals
T282-26
-26 75 μ14971.37 × 46.99 × 25.4Not recordedManufacturer sourceCalculate with this core →
Micrometals
T281-40A
-40 60 μ13071.63 × 38.1 × 16.51Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-292014-2
SM - SenMax™ 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources