My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
Micrometals
HF-292014-2
HF - Hi-Flux™ 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-292014-2
MP - MPP 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-292014-2
FS - FluxSan™ 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-292014-2
MS - Sendust 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-292014-2
SP - SenPreum™ 14 μ4874.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-292026-2
HF - Hi-Flux™ 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-292026-2
MP - MPP 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-292026-2
FS - FluxSan™ 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-292026-2
FX 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-292026-2
OE - Optimized Economy 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-292026-2
OC - Optimized Core Loss 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-292026-2
MS - Sendust 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-292026-2
SP - SenPreum™ 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-292026-2
SM - SenMax™ 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-292026-2
OD - Optimized DC Bias 26 μ8974.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-292040-2
OE - Optimized Economy 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-292040-2
OC - Optimized Core Loss 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-292040-2
MS - Sendust 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-292040-2
SP - SenPreum™ 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-292040-2
SM - SenMax™ 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-292040-2
OD - Optimized DC Bias 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-292040-2
HF - Hi-Flux™ 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-292040-2
MP - MPP 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-292040-2
FS - FluxSan™ 40 μ13774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FX-292060-2
FX 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SM-292060-2
SM - SenMax™ 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OD-292060-2
OD - Optimized DC Bias 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-292060-2
HF - Hi-Flux™ 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MP-292060-2
MP - MPP 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-292060-2
FS - FluxSan™ 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
GX-292060-2
GX - Alloy 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-292060-2
OE - Optimized Economy 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-292060-2
OC - Optimized Core Loss 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
MS-292060-2
MS - Sendust 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
SP-292060-2
SP - SenPreum™ 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HFP-292060-2
HFP 60 μ20674.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
HF-292075-2
HF - Hi-Flux™ 75 μ25774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
FS-292075-2
FS - FluxSan™ 75 μ25774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OC-292075-2
OC - Optimized Core Loss 75 μ25774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →
Micrometals
OE-292075-2
OE - Optimized Economy 75 μ25774.1 × 45.3 × 35Not recordedManufacturer sourceCalculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources