Magnetic Core AL Database
Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.
Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.
Toroid calculator →Matching catalogue records: 6420 / 6420
| Model | Material | AL (nH/N²) | OD × ID × H (mm) | AL tolerance | Manufacturer source | Toroid calculator |
|---|---|---|---|---|---|---|
| KDA KH521-060A | KH 60 μ | 156 | 133.96 × 77.04 × 26.8 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH050-060A-H | KH-H 60 μ | 27 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH065-060A-H | KH-H 60 μ | 35 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH068-060A-H | KH-H 60 μ | 43 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH080-060A-H | KH-H 60 μ | 32 | 21.1 × 12.07 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH090-060A-H | KH-H 60 μ | 43 | 23.62 × 13.39 × 8.38 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH092-060A-H | KH-H 60 μ | 51 | 24.3 × 13.77 × 9.7 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH106-060A-H | KH-H 60 μ | 75 | 27.7 × 14.1 × 11.99 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH107-060A-H | KH-H 60 μ | 59 | 27.7 × 14.1 × 9.45 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH130-060A-H | KH-H 60 μ | 61 | 33.83 × 19.3 × 11.61 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH131-060A-H | KH-H 60 μ | 51 | 33.83 × 19.3 × 9.7 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH132-060A-H | KH-H 60 μ | 65 | 33.83 × 19.3 × 11.99 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH135-060A-H | KH-H 60 μ | 38 | 35.1 × 22.56 × 9.83 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH141-060A-H | KH-H 60 μ | 56 | 36.63 × 21.54 × 11.28 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH157-060A-H | KH-H 60 μ | 81 | 40.72 × 23.3 × 15.37 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH158-060A-H | KH-H 60 μ | 122 | 40.94 × 21.27 × 17.89 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH168-060A-H | KH-H 60 μ | 108 | 44 × 23.3 × 17.16 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH184-060A-H | KH-H 60 μ | 135 | 47.63 × 23.32 × 18.92 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH185-060A-H | KH-H 60 μ | 86 | 47.63 × 27.89 × 16.13 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH200-060A-H | KH-H 60 μ | 73 | 51.69 × 30.94 × 14.35 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH225-060A-H | KH-H 60 μ | 75 | 58 × 34.7 × 14.86 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH226-060A-H | KH-H 60 μ | 138 | 58 × 25.6 × 16.1 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH250-060A-H | KH-H 60 μ | 192 | 63.1 × 31.37 × 26.27 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH268-060A-H | KH-H 60 μ | 143 | 69.4 × 34.7 × 21.4 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH300-060A-H | KH-H 60 μ | 68 | 78.9 × 48.2 × 13.84 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH301-060A-H | KH-H 60 μ | 85 | 78.9 × 48.2 × 17.02 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KH400-060A-H | KH-H 60 μ | 112 | 103.12 × 55.75 × 17.78 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM050-026A | KAM 26 μ | 12 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM050-060A | KAM 60 μ | 27 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM050-075A | KAM 75 μ | 34 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM050-090A | KAM 90 μ | 40 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM050-125A | KAM 125 μ | 56 | 13.46 × 6.99 × 5.51 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM065-026A | KAM 26 μ | 15 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM065-060A | KAM 60 μ | 35 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM065-075A | KAM 75 μ | 43 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM065-090A | KAM 90 μ | 52 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM065-125A | KAM 125 μ | 72 | 17.4 × 9.53 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM068-026A | KAM 26 μ | 19 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM068-060A | KAM 60 μ | 43 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
| KDA KAM068-075A | KAM 75 μ | 53 | 18.03 × 9.02 × 7.11 | Not recorded | Manufacturer source | Calculate with this core → |
Engineering questions
Does AL remain constant under DC bias?
No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.
Why can 20 turns fall short of the target inductance?
N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.
Will a larger wire diameter still fit?
Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.