My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
KDA
KAM068-090A
KAM 90 μ6418.03 × 9.02 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM068-125A
KAM 125 μ8918.03 × 9.02 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM080-026A
KAM 26 μ1421.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM080-060A
KAM 60 μ3221.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM080-075A
KAM 75 μ4121.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM080-090A
KAM 90 μ4921.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM080-125A
KAM 125 μ6821.1 × 12.07 × 7.11Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-026A
KAM 26 μ1923.62 × 13.39 × 8.38Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-026A-E14
KAM 26 μ3523.62 × 13.39 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-060A
KAM 60 μ4323.62 × 13.39 × 8.38Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-060A-E14
KAM 60 μ7923.62 × 13.39 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-075A
KAM 75 μ5423.62 × 13.39 × 8.38Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-075A-E14
KAM 75 μ9923.62 × 13.39 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-090A
KAM 90 μ6523.62 × 13.39 × 8.38Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-090A-E14
KAM 90 μ11923.62 × 13.39 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-125A
KAM 125 μ9023.62 × 13.39 × 8.38Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM090-125A-E14
KAM 125 μ16523.62 × 13.39 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-026A
KAM 26 μ2224.3 × 13.77 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-026A-E14
KAM 26 μ3524.3 × 13.77 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-026A-E18
KAM 26 μ4524.3 × 13.77 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-060A
KAM 60 μ5124.3 × 13.77 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-060A-E14
KAM 60 μ8024.3 × 13.77 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-060A-E18
KAM 60 μ10324.3 × 13.77 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-075A
KAM 75 μ6324.3 × 13.77 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-075A-E14
KAM 75 μ9924.3 × 13.77 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-075A-E18
KAM 75 μ12824.3 × 13.77 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-090A
KAM 90 μ7624.3 × 13.77 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-090A-E14
KAM 90 μ12024.3 × 13.77 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-090A-E18
KAM 90 μ15424.3 × 13.77 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-125A
KAM 125 μ10524.3 × 13.77 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-125A-E14
KAM 125 μ16524.3 × 13.77 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM092-125A-E18
KAM 125 μ21324.3 × 13.77 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-026A
KAM 26 μ3227.7 × 14.1 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-026A-E14
KAM 26 μ4027.7 × 14.1 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-026A-E18
KAM 26 μ5127.7 × 14.1 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-060A
KAM 60 μ7527.7 × 14.1 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-060A-E14
KAM 60 μ9427.7 × 14.1 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-060A-E18
KAM 60 μ12027.7 × 14.1 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-075A
KAM 75 μ9427.7 × 14.1 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-075A-E14
KAM 75 μ11827.7 × 14.1 × 15Not recordedManufacturer source
PDF
Calculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources