My favorites

Magnetic Core AL Database

Browse source-linked magnetic core AL values and dimensions, then calculate turns and review winding feasibility with the selected core.

Catalogue AL is nominal. Original documentation and application measurements are required for bias, temperature and current qualification. Missing tolerance or bias data stays unknown. Dimensions follow the source convention; coating is not always specified.

Toroid calculator →

Matching catalogue records: 6420 / 6420

ModelMaterialAL (nH/N²)OD × ID × H (mm)AL toleranceManufacturer sourceToroid calculator
KDA
KAM106-075A-E18
KAM 75 μ15127.7 × 14.1 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-090A
KAM 90 μ11327.7 × 14.1 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-090A-E14
KAM 90 μ14127.7 × 14.1 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-090A-E18
KAM 90 μ18127.7 × 14.1 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-125A
KAM 125 μ15727.7 × 14.1 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-125A-E14
KAM 125 μ19627.7 × 14.1 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM106-125A-E18
KAM 125 μ25227.7 × 14.1 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM107-026A
KAM 26 μ2227.7 × 14.1 × 9.45Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM107-060A
KAM 60 μ5927.7 × 14.1 × 9.45Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM107-075A
KAM 75 μ7427.7 × 14.1 × 9.45Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM107-090A
KAM 90 μ8927.7 × 14.1 × 9.45Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM107-125A
KAM 125 μ12327.7 × 14.1 × 9.45Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-026A
KAM 26 μ2833.83 × 19.3 × 11.61Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-026A-E14
KAM 26 μ3733.83 × 19.3 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-026A-E18
KAM 26 μ4733.83 × 19.3 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-060A
KAM 60 μ6133.83 × 19.3 × 11.61Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-060A-E14
KAM 60 μ8033.83 × 19.3 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-060A-E18
KAM 60 μ10333.83 × 19.3 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-075A
KAM 75 μ7633.83 × 19.3 × 11.61Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-075A-E14
KAM 75 μ9933.83 × 19.3 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-075A-E18
KAM 75 μ12833.83 × 19.3 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-090A
KAM 90 μ9133.83 × 19.3 × 11.61Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-090A-E14
KAM 90 μ11933.83 × 19.3 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-090A-E18
KAM 90 μ15333.83 × 19.3 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-125A
KAM 125 μ12733.83 × 19.3 × 11.61Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-125A-E14
KAM 125 μ16633.83 × 19.3 × 15Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM130-125A-E18
KAM 125 μ21433.83 × 19.3 × 19Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM131-026A
KAM 26 μ2233.83 × 19.3 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM131-060A
KAM 60 μ5133.83 × 19.3 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM131-075A
KAM 75 μ6433.83 × 19.3 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM131-090A
KAM 90 μ76.533.83 × 19.3 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM131-125A
KAM 125 μ10933.83 × 19.3 × 9.7Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM132-026A
KAM 26 μ2833.83 × 19.3 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM132-060A
KAM 60 μ6533.83 × 19.3 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM132-075A
KAM 75 μ8133.83 × 19.3 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM132-090A
KAM 90 μ9733.83 × 19.3 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM132-125A
KAM 125 μ13533.83 × 19.3 × 11.99Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM135-026A
KAM 26 μ1635.1 × 22.56 × 9.83Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM135-060A
KAM 60 μ3835.1 × 22.56 × 9.83Not recordedManufacturer source
PDF
Calculate with this core →
KDA
KAM135-075A
KAM 75 μ4735.1 × 22.56 × 9.83Not recordedManufacturer source
PDF
Calculate with this core →

Engineering questions

Does AL remain constant under DC bias?

No. Nominal catalogue AL does not establish loaded inductance. Use the exact material and core bias curve at the intended current and temperature. A missing curve is not a pass.

Why can 20 turns fall short of the target inductance?

N = √(L/AL) is a nominal calculation with consistent units. AL tolerance, DC bias, integer-turn rounding and winding conditions can change the achieved inductance; verify the finished winding.

Will a larger wire diameter still fit?

Check finished enamel diameter, parallel strands, inner-hole clearance and winding layers. The calculator provides a geometric estimate, not winding-process or thermal qualification.

Resources