My favorites

TDK SPM10054T-2R5M-HZ vs HZR: Ratings and Replacement Review

TDK recommends SPM10054T-2R5M-HZR after the NRND SPM10054T-2R5M-HZ, but explicitly does not guarantee interchangeability. Equal nominal inductance and similar mechanical dimensions do not establish a qualified replacement.

1. Start from the lifecycle notice

NRND means not recommended for new designs; it does not by itself mean immediate discontinuation or confirmed stock. Keep the current manufacturer notice with the exact old and new ordering codes.

2. Separate the two current definitions

Both records use a typical 20% inductance decrease for the saturation reference and a typical 40°C rise for the thermal reference. HZ lists 11.8 A and 19 A respectively; HZR lists 13.9 A and 13.2 A. Do not combine them into a single safe-current figure. [1][2]

3. Review loss and mechanical conditions

HZ maximum DCR is 6.58 mΩ; HZR is 7.48 mΩ. Both list 2.5 µH ±20% at 100 kHz and 5.40 mm maximum height. Compare the latest dimensional drawings, tolerances and land pattern, then calculate losses at the actual winding temperature. [1][2]

4. Validate the original application

Record RMS and peak current, ripple, switching frequency, input/output range, ambient, PCB copper and airflow. Check bias curves and hot inductance, transient behavior, temperature rise and any controller stability constraints. Retain the test setup and acceptance limits.

5. Approve only after review

Use the original and successor documentation with your circuit results. A manufacturer recommendation narrows the investigation; it does not replace engineering or production approval.

Parameter review table

Recorded conditionHZ — original [1]HZR — successor [2]
Manufacturer statusProduction (NRND)Production
Inductance2.5 µH ±20% at 100 kHz2.5 µH ±20% at 100 kHz
Saturation current, typical, 20% L decrease11.8 A13.9 A
Thermal current, typical, 40°C rise19 A13.2 A
DCR typical / maximum5.98 / 6.58 mΩ6.8 / 7.48 mΩ
Height maximum5.40 mm5.40 mm

Put the review into practice

An application with acceptable peak-current margin can still exceed a thermal limit after a change. Conversely, a cooler winding does not prove adequate inductance under peak bias. Recalculate both checks with the application waveform; no safe board current or measured temperature is inferred from this table.

Frequently asked questions

Is HZR a guaranteed drop-in replacement for HZ?

No. TDK explicitly warns that interchangeability is not guaranteed. Review the exact documents and validate the board.

Why does saturation current increase while thermal current decreases?

They measure different constraints. The typical saturation reference follows a stated inductance drop; the thermal reference follows temperature rise. These numbers alone do not identify the internal design changes or prove a thermal cause.

Does NRND mean the original part is already discontinued?

Not necessarily. Check the current lifecycle notice and supplier confirmation; NRND alone is not an end-of-life date or a stock promise.

Exact-part examples and evidence

SPM10054T-2R5M-HZ

The original record labels HZ Production (NRND) and recommends HZR while explicitly withholding a guarantee of interchangeability. Check the live manufacturer status and exact documentation before a new design or production change.

Open catalogue recordOpen cited documentation

SPM10054T-2R5M-HZR

The HZR record is a manufacturer-recommended successor research entry, not an automatic drop-in approval. Its higher typical saturation reference and lower typical thermal reference constrain different aspects of the design.

Open catalogue recordOpen cited documentation

Original technical references

  1. TDK — SPM10054T-2R5M-HZ original product record (NRND)
  2. TDK — SPM10054T-2R5M-HZR original product record

Check the latest documentation for the full ordering code and validate the intended circuit before ordering or substituting a part.

Explore the guides

Engineering tools and catalogue

Send a selection inquiry